The new DS Power range UPS uses the latest DSP technology to be programmed to suit a wide variety of electrical environments without impending its performance. With the DS Power range, efficiency, reliability and functionality are enhanced to levels unattainable with the old analogue technology. This technology does not only create significant increase in MTBF, but the capability of DSP to accurately manipulate signals at very high speed permits all the UPS subsystems to be controlled with greatly increased precision
GENERAL SPECIFICATIONS
• Transformerless UPS topology
• Low input current total harmonic distortion (THD)
• High input power factor
• High efficiency up to 94.5%
• Cold start function
• Static and maintenance by-pass switch
• Output short circuit and overload protection
• External REPO switch input
• 512 events memory (512 events 45000 alarms)
• Clock and calender (battery supported)
• Automatic battery test,remaining battery time indicator
• Temperature compansated charge system (optional)
• 2 RS232 serial ports and 12 dry contact outputs
• 3 DSP controlled modular structure
• Optional graphical panel
• Optional usb flash memory
• Optional SNMP and MODBUS adaptors
• Manufactured according to EC Directive; EN62040
• Full digital structure
• Small footprint
• Ecomode operation (optional)
• Fewer electronic components
• Output current limiting
• Advanced diagnostics for the input
• Selectable input/output voltage/frequency/range
• Split by-pass input (second input)
• Output DC leakage protection
• Separate DSP for inverter control
• Separate DSP for the PFC
• 3 level battery protection
• High charge current capacity
• Charge/discharge current indicator
• Advanced remote control
• 2 years warranty
TECHNICIAL SPECIFICATIONS
TECHNICIAL SPECIFICATIONS | |
Güç (kVA=kW) | 500 |
INPUT | |
Voltage | 380/400 VAC 3P + N + G ± 20% (415 VAC +15%, - 25% optional) |
Frequency | 50Hz / 60Hz , ± 10% |
Power factor (at100% load) | ≥ 0.99 |
THDI (*) | ≤ %3 |
By-Pass Voltage | 380/400 VAC 3 Phase + N, ± 10% |
Protection | Fuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator |
OUTPUT | |
Power (kW) | 500 |
Power factor | 1 |
Voltage | 380/400 VAC 3 Phase + N , ± 1% (415 optional) |
Frequency | 50Hz / 60Hz |
Frequency Tolerance | Line synchronized: ± 2% (adjustable) / Free running: ± 0,1% |
Efficiency (at 100% load) | up to 95% |
Output current crest factor | 3:1 |
Overload Protection | 100% - 125% load: 10 min, 125% - 150% load: 1 min, - > 150% load: by pass |
Other Protections | Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting |
THD | ≤ 2% (at 100% linear load) |
BATTERIES | |
Type | VRLA AGM / GEL / NiCd |
Battery Number | ± 360 VDC (2x30 batteries) |
Float charging voltage | 2x405 VDC |
Float / End of dischg voltage | ± 405 VDC / ± 300 VDC |
Battery Housing | External |
Battery ambient temp | 25ºC |
Protections | 3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional) |
Automatic Testing | Standard every 72 hours (adjustable) |
GENEL | |
Standards | EN62040-1, EN62040-2, EN62040-3 |
User Interface | 5 vector buttons, Buzzer, TFT panel |
Indicators | P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time |
Advanced | Self diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter |
Communication | 2xRS232 serial ports, 4 standard and 8 optional DRY contact alarm relays |
Inputs | EPO input, Interactive battery panel input, Genset input |
Genset Kit | Standard (programmable) |
Soſtware | Standard T-Mon UPS Management Soſtware (3 clients + 1 server management) |
Alarm Logging | Standard:with time & date 512 events |
Protections | Power module over-temperature, Overcurrent, Temperature high alarm |
Temperature Range | 0ºC - 40ºC |
Protection class | IP20 |
Relative humidity | 90% max. (non-condensing) |
Altitude | < 1000m above sea level |
Noise level | < 72 dBA |
Weight (kg) | 1452 |
Dimension (mm) HxWxD | 1610x1050x1940 |
OPTIONS | |
Input / Output voltage | Please ask |
Transformer | Galvanic isolation transformer at the input & output (internal) |
Soſtware | T-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 10-50-100-200 clients |
Comm. adaptors | SNMP, RS485, Remote monitoring panel, MODBUS (RS485 or TCP/IP), USB Alarm Logger, TCP/IP, GSM/GPRS Modem, Comport multiplexer |
Parralel Operation | Up to 8 units |
Power factor | Opsiyonel olarak 0.8 yapılır. Ancak boyutlarda değişiklik gösterebilir. |
(*) | Depending on power and input/output conditions |
TECHNICIAL SPECIFICATIONS | |
Güç (kVA=kW) | 600 |
INPUT | |
Voltage | 380/400 VAC 3P + N + G ± 20% (415 VAC +15%, - 25% optional) |
Frequency | 50Hz / 60Hz , ± 10% |
Power factor (at100% load) | ≥ 0.99 |
THDI (*) | ≤ %3 |
By-Pass Voltage | 380/400 VAC 3 Phase + N, ± 10% |
Protection | Fuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator |
OUTPUT | |
Power (kW) | 600 |
Power factor | 1 |
Voltage | 380/400 VAC 3 Phase + N , ± 1% (415 optional) |
Frequency | 50Hz / 60Hz |
Frequency Tolerance | Line synchronized: ± 2% (adjustable) / Free running: ± 0,1% |
Efficiency (at 100% load) | up to 95% |
Output current crest factor | 3:1 |
Overload Protection | 100% - 125% load: 10 min, 125% - 150% load: 1 min, - > 150% load: by pass |
Other Protections | Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting |
THD | ≤ 2% (at 100% linear load) |
BATTERIES | |
Type | VRLA AGM / GEL / NiCd |
Battery Number | ± 360 VDC (2x30 batteries) |
Float charging voltage | 2x405 VDC |
Float / End of dischg voltage | ± 405 VDC / ± 300 VDC |
Battery Housing | External |
Battery ambient temp | 25ºC |
Protections | 3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional) |
Automatic Testing | Standard every 72 hours (adjustable) |
GENEL | |
Standards | EN62040-1, EN62040-2, EN62040-3 |
User Interface | 5 vector buttons, Buzzer, TFT panel |
Indicators | P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time |
Advanced | Self diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter |
Communication | 2xRS232 serial ports, 4 standard and 8 optional DRY contact alarm relays |
Inputs | EPO input, Interactive battery panel input, Genset input |
Genset Kit | Standard (programmable) |
Soſtware | Standard T-Mon UPS Management Soſtware (3 clients + 1 server management) |
Alarm Logging | Standard:with time & date 512 events |
Protections | Power module over-temperature, Overcurrent, Temperature high alarm |
Temperature Range | 0ºC - 40ºC |
Protection class | IP20 |
Relative humidity | 90% max. (non-condensing) |
Altitude | < 1000m above sea level |
Noise level | < 72 dBA |
Weight (kg) | 1452 |
Dimension (mm) HxWxD | 1610x1050x1940 |
OPTIONS | |
Input / Output voltage | Please ask |
Transformer | Galvanic isolation transformer at the input & output (internal) |
Soſtware | T-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 10-50-100-200 clients |
Comm. adaptors | SNMP, RS485, Remote monitoring panel, MODBUS (RS485 or TCP/IP), USB Alarm Logger, TCP/IP, GSM/GPRS Modem, Comport multiplexer |
Parralel Operation | Up to 8 units |
Power factor | Opsiyonel olarak 0.8 yapılır. Ancak boyutlarda değişiklik gösterebilir. |
(*) | Depending on power and input/output conditions |